cimpy.cgmes_v2_4_15.WindPlantReactiveControlIEC module¶
-
class
cimpy.cgmes_v2_4_15.WindPlantReactiveControlIEC.
WindPlantReactiveControlIEC
(WindPlantIEC=None, kiwpx=0.0, kpwpx=0.0, kwpqu=0.0, mwppf=False, mwpu=False, twppfilt=0, twpqfilt=0, twpufilt=0, txft=0, txfv=0, uwpqdip=0.0, xrefmax=0.0, xrefmin=0.0, *args, **kw_args)[source]¶ Simplified plant voltage and reactive power control model for use with type 3 and type 4 wind turbine models. Reference: IEC Standard 61400-27-1 Annex E.
- WindPlantIEC
Wind plant model with which this wind reactive control is associated. Default: None
- kiwpx
Plant Q controller integral gain (). It is type dependent parameter. Default: 0.0
- kpwpx
Plant Q controller proportional gain (). It is type dependent parameter. Default: 0.0
- kwpqu
Plant voltage control droop (). It is project dependent parameter. Default: 0.0
- mwppf
Power factor control modes selector (). Used only if mwpu is set to false. true = 1: power factor control false = 0: reactive power control. It is project dependent parameter. Default: False
- mwpu
Reactive power control modes selector (). true = 1: voltage control false = 0: reactive power control. It is project dependent parameter. Default: False
- twppfilt
Filter time constant for active power measurement (). It is type dependent parameter. Default: 0
- twpqfilt
Filter time constant for reactive power measurement (). It is type dependent parameter. Default: 0
- twpufilt
Filter time constant for voltage measurement (). It is type dependent parameter. Default: 0
- txft
Lead time constant in reference value transfer function (). It is type dependent parameter. Default: 0
- txfv
Lag time constant in reference value transfer function (). It is type dependent parameter. Default: 0
- uwpqdip
Voltage threshold for LVRT detection in q control (). It is type dependent parameter. Default: 0.0
- xrefmax
Maximum ( or delta ) request from the plant controller (). It is project dependent parameter. Default: 0.0
- xrefmin
Minimum ( or delta) request from the plant controller (). It is project dependent parameter. Default: 0.0
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects
The domain object to which this diagram object is associated. Default: “list”
- mRID
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- shortName
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’
-
cgmesProfile
¶ alias of
cimpy.cgmes_v2_4_15.Base.Profile