cimpy.cgmes_v2_4_15.WindPlantFreqPcontrolIEC module¶
-
class
cimpy.cgmes_v2_4_15.WindPlantFreqPcontrolIEC.
WindPlantFreqPcontrolIEC
(WindDynamicsLookupTable='list', dprefmax=0.0, dprefmin=0.0, kiwpp=0.0, kpwpp=0.0, prefmax=0.0, prefmin=0.0, tpft=0, tpfv=0, twpffilt=0, twppfilt=0, WindPlantIEC=None, *args, **kw_args)[source]¶ Frequency and active power controller model. Reference: IEC Standard 61400-27-1 Annex E.
- WindDynamicsLookupTable
The frequency and active power wind plant control model with which this wind dynamics lookup table is associated. Default: “list”
- dprefmax
Maximum ramp rate of request from the plant controller to the wind turbines (). It is project dependent parameter. Default: 0.0
- dprefmin
Minimum (negative) ramp rate of request from the plant controller to the wind turbines (). It is project dependent parameter. Default: 0.0
- kiwpp
Plant P controller integral gain (). It is type dependent parameter. Default: 0.0
- kpwpp
Plant P controller proportional gain (). It is type dependent parameter. Default: 0.0
- prefmax
Maximum request from the plant controller to the wind turbines (). It is type dependent parameter. Default: 0.0
- prefmin
Minimum request from the plant controller to the wind turbines (). It is type dependent parameter. Default: 0.0
- tpft
Lead time constant in reference value transfer function (). It is type dependent parameter. Default: 0
- tpfv
Lag time constant in reference value transfer function (). It is type dependent parameter. Default: 0
- twpffilt
Filter time constant for frequency measurement (). It is type dependent parameter. Default: 0
- twppfilt
Filter time constant for active power measurement (). It is type dependent parameter. Default: 0
- WindPlantIEC
Wind plant model with which this wind plant frequency and active power control is associated. Default: None
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects
The domain object to which this diagram object is associated. Default: “list”
- mRID
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- shortName
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’
-
cgmesProfile
¶ alias of
cimpy.cgmes_v2_4_15.Base.Profile