cimpy.cgmes_v2_4_15.TopologicalNode module¶
-
class
cimpy.cgmes_v2_4_15.TopologicalNode.
TopologicalNode
(SvInjection=None, SvVoltage=None, AngleRefTopologicalIsland=None, TopologicalIsland=None, BaseVoltage=None, ConnectivityNodes='list', ConnectivityNodeContainer=None, ReportingGroup=None, Terminal='list', boundaryPoint=False, fromEndIsoCode='', fromEndName='', fromEndNameTso='', toEndIsoCode='', toEndName='', toEndNameTso='', *args, **kw_args)[source]¶ For a detailed substation model a topological node is a set of connectivity nodes that, in the current network state, are connected together through any type of closed switches, including jumpers. Topological nodes change as the current network state changes (i.e., switches, breakers, etc. change state). For a planning model, switch statuses are not used to form topological nodes. Instead they are manually created or deleted in a model builder tool. Topological nodes maintained this way are also called “busses”.
- SvInjection
The topological node associated with the flow injection state variable. Default: None
- SvVoltage
The topological node associated with the voltage state. Default: None
- AngleRefTopologicalIsland
The island for which the node is an angle reference. Normally there is one angle reference node for each island. Default: None
- TopologicalIsland
A topological node belongs to a topological island. Default: None
- BaseVoltage
The base voltage of the topologocial node. Default: None
- ConnectivityNodes
The topological node to which this connectivity node is assigned. May depend on the current state of switches in the network. Default: “list”
- ConnectivityNodeContainer
The connectivity node container to which the toplogical node belongs. Default: None
- ReportingGroup
The topological nodes that belong to the reporting group. Default: None
- Terminal
The topological node associated with the terminal. This can be used as an alternative to the connectivity node path to topological node, thus making it unneccesary to model connectivity nodes in some cases. Note that the if connectivity nodes are in the model, this association would probably not be used as an input specification. Default: “list”
- boundaryPoint
Identifies if a node is a BoundaryPoint. If boundaryPoint=true the ConnectivityNode or the TopologicalNode represents a BoundaryPoint. Default: False
- fromEndIsoCode
The attribute is used for an exchange of the ISO code of the region to which the From side of the Boundary point belongs to or it is connected to. The ISO code is two characters country code as defined by ISO 3166 (). The length of the string is 2 characters maximum. The attribute is a required for the Boundary Model Authority Set where this attribute is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
- fromEndName
The attribute is used for an exchange of a human readable name with length of the string 32 characters maximum. The attribute covers two cases: The attribute is required for the Boundary Model Authority Set where it is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
- fromEndNameTso
The attribute is used for an exchange of the name of the TSO to which the From side of the Boundary point belongs to or it is connected to. The length of the string is 32 characters maximum. The attribute is required for the Boundary Model Authority Set where it is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
- toEndIsoCode
The attribute is used for an exchange of the ISO code of the region to which the To side of the Boundary point belongs to or it is connected to. The ISO code is two characters country code as defined by ISO 3166 (). The length of the string is 2 characters maximum. The attribute is a required for the Boundary Model Authority Set where this attribute is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
- toEndName
The attribute is used for an exchange of a human readable name with length of the string 32 characters maximum. The attribute covers two cases: The attribute is required for the Boundary Model Authority Set where it is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
- toEndNameTso
The attribute is used for an exchange of the name of the TSO to which the To side of the Boundary point belongs to or it is connected to. The length of the string is 32 characters maximum. The attribute is required for the Boundary Model Authority Set where it is used only for the TopologicalNode in the Boundary Topology profile and ConnectivityNode in the Boundary Equipment profile. Default: ‘’
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects
The domain object to which this diagram object is associated. Default: “list”
- mRID
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- shortName
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’
-
cgmesProfile
¶ alias of
cimpy.cgmes_v2_4_15.Base.Profile