cimpy.cgmes_v2_4_15.DCShunt module¶
-
class
cimpy.cgmes_v2_4_15.DCShunt.
DCShunt
(capacitance=0.0, resistance=0.0, ratedUdc=0.0, *args, **kw_args)[source]¶ A shunt device within the DC system, typically used for filtering. Needed for transient and short circuit studies.
- capacitance
Capacitance of the DC shunt. Default: 0.0
- resistance
Resistance of the DC device. Default: 0.0
- ratedUdc
Rated DC device voltage. Converter configuration data used in power flow. Default: 0.0
Documentation of parent class DCConductingEquipment:
The parts of the DC power system that are designed to carry current or that are conductively connected through DC terminals.
- DCTerminals
Default: “list”
Documentation of parent class Equipment:
The parts of a power system that are physical devices, electronic or mechanical.
- aggregate
The single instance of equipment represents multiple pieces of equipment that have been modeled together as an aggregate. Examples would be power transformers or synchronous machines operating in parallel modeled as a single aggregate power transformer or aggregate synchronous machine. This is not to be used to indicate equipment that is part of a group of interdependent equipment produced by a network production program. Default: False
- EquipmentContainer
Container of this equipment. Default: None
- OperationalLimitSet
The operational limit sets associated with this equipment. Default: “list”
Documentation of parent class PowerSystemResource:
A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.
- Controls
Regulating device governed by this control output. Default: “list”
- Measurements
The power system resource that contains the measurement. Default: “list”
- Location
Location of this power system resource. Default: None
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects
The domain object to which this diagram object is associated. Default: “list”
- mRID
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- shortName
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’
-
cgmesProfile
¶ alias of
cimpy.cgmes_v2_4_15.Base.Profile